humidity: Make humidity measurement initialisation more robust

The RHT03 has problems in synchronising with the â€˜start’ signal sent by the
microcontroller if the RHT03 has previously been power gated. The changes in
this commit go some way to improving this, but unfortunately the only
reliable solution seems to be to not gate power to the RHT03 in the first
place. Sigh. At least its current consumption is only 3mA.